Comparative study of dog blood counts in semi-automated systems and manual at the Veterinary Clinical Laboratory of the UEMASUL

Estudo comparado dos hemogramas de cães em sistemas semiautomatizado e manual no Laboratório Clínico Veterinário da UEMASUL

Autores

Resumo

The hemogram is a fundamental complementary exam in veterinarian medicine field that assess the health of the animals. The Blood count provides crucial information about the cellular elements in the blood, being essential for detecting and monitoring several clinical conditions in animals. The main purpose was to compare the results achieved in the hematological variables of erythrocytes, hematocrit, MCV, total leukocytes and platelets in hemograms of dogs obtained using the methods semi-automated and manual. The result exhibit that, based on a set of 10 samples, there were no significant differences between the methods. However, when all 24 samples were analyzed, significant differences in total erythrocyte and leukocyte levels were observed between the two methods.

Downloads

Não há dados estatísticos.

Referências

ALMOSNY, Nádia Regina Pereira; CORREIA DOS SANTOS, Leonilda. Laboratory support in wild animal medicine. Biology, medicine, and surgery of south American wild animals, p. 500-505, 2001.

BACALL, Nydia S. Analisador automático hematológico e a importância de validar novos equipamentos em laboratórios clínicos. Revista Brasileira de Hematologia e Hemoterapia, v.31, n.4, p. 218-220, 2009.

BAIN, B.J. Células sanguíneas: um guia prático. 4º ed, Artmed, São Paulo, 2006

BANDEIRA, Ricardo; MAGALHÃES, Andressa Figueiredo; AQUINO, Hugo Bastos da Silva. interpretação dos critérios de liberação dos resultados de hemograma através de contadores automatizados em laboratório de urgência. Revista Saúde e Pesquisa, v. 7, n. 3, p. 403-408, 2014.

BERNARDO, Fábio D. et al. Importance of blood smear in the distinction of hemoparasites: A case report of anaplasmosis. Revista Brasileira de Higiene e Sanidade Animal, v.10, n.2, p. 290-296, 2016.

BORGES, Alexandre Secorun et al. Evaluation of zebu nellore cattle blood samples using the Cell-Dyn 3500 hematology analyzer. Ciência Animal Brasileira, v. 15, p. 466-472, 2014.

CADENA-HERRERA, Daniela et al. Validation of three viable-cell counting methods: Manual, semi-automated, and automated. Biotechnology Reports, v. 7, p. 9-16, 2015.

CARMO, Blênio Magno Bernardes et al. Hemograma completo: ferramenta de diagnóstico na medicina veterinária. Brazilian Journal of Development, v. 6, n. 7, p. 49989-49994, 2020.

COMAR, Samuel R. et al. Contagem de plaquetas: avaliação de metodologias manuais e aplicação na rotina laboratorial. Revista Brasileira de Hematologia e Hemoterapia, v. 31, n. 6, p. 431-436, 2009.

CORRONS, J.L.V.; BASCOMPTE, J.L.A. Manual de técnicas de laboratorio en Hematología. Espanha: Elsevier, 2006. p.95-97.

DE MELO, Márcio Antonio Wanderley; DA SILVEIRA, Cristina Magalhães. Laboratório de Hematologia–Teorias, Técnicas e Atlas. Editora Rubio, 2014.

DENICOLA, Dennis B. Advances in hematology analyzers. Topics in companion animal medicine, v. 26, n. 2, p. 52-61, 2011.

DE SANTIS, Gil Cunha. Anemia: definição, epidemiologia, fisiopatologia, classificação e tratamento. Medicina (Ribeirão Preto), v. 52, n. 3, p. 239-251, 2019.

DE SOUZA, Kamila Líbano; FALBO, Margarete Kimie. Efeito do tempo e da temperatura de armazenamento nos parâmetros hematológicos de cães hígidos. Pubvet, v. 14, p. 148, 2020.

DIAZ GONZÁLEZ, Félix H.; SILVA, S. C. Patologia clínica veterinária: texto introdutório. Porto Alegre: Universidade Federal do Rio Grande do Sul, 2008.

DINIZ, Cryslayne Clara Espínola et al. A automação no hemograma e sua evolução. 2015.

ENGLAND, J. M.; WALFORD, D. M.; WATERS, D. A. W. Re‐assessment of the reliability of the haematocrit. British journal of haematology, v. 23, n. 2, p. 247-256, 1972.

FAILACE, Rafael; PRANKE, Patrícia. Avaliação dos critérios de liberação direta dos resultados de hemogramas através de contadores eletrônicos. Revista brasileira de hematologia, 2004.

GROTTO, H. Z. W. O hemograma: importância para a interpretação da biopsia. Ver. Bras. Hematol Hemoter, v.31, n.3, p.178-182, 2009.

HEMOGRAM. Manual do usuário do analisador de hematologia Hemacounter 60-rt-7600. Corporação rayto life and analytical sciences co., ltda. Ver.2.0e

JAIN, N.C. Schalm’s Veterinary Hematology. 4.ed. Philadelphia: Lea & Febiger, 1986. 1221p.

LOPES, Sonia Terezinha dos Anjos; BIONDO, Alexander Welker; SANTOS, Andrea Pires, dos. Manual de patologia clínica veterinária. 3.ed. UFSMCCR. Departamento de clínica de pequenos animais, 2007.

LONGA, Camila et al. PADRONIZAÇÃO DO ANALISADOR HEMATOLÓGICO AUTOMATIZADO VETERINÁRIO Sysmex pocH-100iV Diff PARA MICOS-DE-CHEIRO, Saimiri sciureus (PRIMATES: CEBIDAE). Enciclopédia Biosfera, v. 10, n. 19, 2014.

MELLO, M.H. N-acetilcisteína e dapsona: avaliação da toxicidade hematológica e bioquímica em ratos Wistar. 2005. 103p. Dissertação (Mestrado em Toxicologia). Programa de Pós-graduação em Toxicologia, Universidade de São Paulo.

MESSIAS, J. B. Parâmetros hematológicos de Rattus norvegicus obtidos através de método automatizado e não automatizado. Medicina Veterinária (UFRPE), v. 3, n. 2, p. 1-8, 2009.

MICHELSON, A.D. Flow Citometry: a clinical test of platelet function. Blood, v.87, n.12, p.4925- 4936, 1996.

MUNHOZ, Marcos Antonio Gonçalves et al. Determinação de valores-alvo para uso no controle de qualidade de analisadores hematológicos. Revista do Instituto Adolfo Lutz, v. 53, n. 1-2, p. 41-7, 1993.

NAOUM, Paulo Cesar. Anemias: classificação e diagnóstico diferencial. São Paulo: Universidade Estadual Paulista, 2015.

NASCIMENTO, M.L.P; SILVA, L.L. Comparação da frequência de morfologias eritrocitárias adquiridas entre as avaliações por automação e por estudo morfológico. Labor News, 2006.

OLIVEIRA, R.A.G.; Hemograma: como fazer e interpretar. São Paulo: livraria médica paulista editora, 2007.

RIZZI, T. E.; MEINKOTH, J. H.; CLINKENBEARD, K. D. Normal Hematology of the Dog. In: WEISS, D. J; WARDROP, J. K. Schalm’s Veterinary Hematology. 6th ed. Oxford: Wiley-Blackwell, 2010. p.799-810.

SANTOS, Lucas B.C.; LEME, Fabiola O.P. Comparação entre metodologias analíticas para a realização de hemogramas em Medicina Veterinária. Revista V & Z em Minas, n148, p.29-37, 2021.

SCHWEIRGERT, Augusto et al. Avaliação da contagem plaquetária pelo contador automático QBC Vet Autoread® comparado com estimativa em esfregaço sanguíneo e contagem em hemocitômetro. Semina: Ciências Agrárias, v. 31, n. 4, p. 1001-1008, 2010.

SILVA, H. P. Et al. Hematologia laboratorial: teoria e procedimentos. Porto alegre: Artmed, 2016.

SILVA, Malena Noro, 1978 –. Hematologia veterinária / Malena Noro Silva. – Belém: EditAEDI-. UFPA, 2017. 116 p. :il. ISBN: 978-85-65054-52-2.

TEMIZEL, E. M.; CIHAN, H.; YILMAZ, Z.; AYTUG, N. Evaluation of erythrocyte and platelet indices in canine visceral leishmaniasis. Ankara Üniv Vet Fak Derg, v.58, p.185-188, 2011.

VALLADA, E. P. Manual de técnicas hematológicas. São Paulo: Atheneu, p.423, 1999.

VELOSO et al. Avaliação dos critérios adotados no interfaceamento dos resultados dos hemogramas automatizados. Revista saúde e ambiente, 2011.

VIVES-CORRONS, Joan-Lluis et al. Evaluation of the Abbott Cell-DYN 3500 hematology analyzer in a university hospital. American journal of clinical pathology, v. 105, n. 5, p. 553-559, 1996.

THRALL, M. A. et al. Hematologia e Bioquímica Clínica Veterinária. 2 ed. São Paulo: Roca, 2015. p. 21-186.

Downloads

Publicado

2024-03-21

Edição

Seção

Articles