Use of ultrasound applied to the peripherally inserted central catheter in newborns

Utilização da ultrassonografia aplicada ao cateter central de inserção periférica em recém-nascidos

Autores

  • Kananda Freitas Universidade de Brasília
  • Laiane Ribeiro
  • Lucas Lima
  • Ludmylla Beleza
  • Giselle Santana
  • Larissa Nascimento
  • Casandra Ponce de Leon
  • Juliana Schardosim

DOI:

https://doi.org/10.53660/CLM-3533-24L02

Palavras-chave:

Newborn, Neonatal Nursing, Interventional Ultrasonography, Peripheral Catheterization

Resumo

Objective: to report the experience of using ultrasound applied to the Peripherally Inserted Central Catheter (PICC) in hospitalized newborns. Method: this is a descriptive study of the experience report type, involving newborns that were subject to PICC insertion in a highly complex teaching hospital. Results: it was possible to visualize the PICC tip in the superior vena cava in 70% of the procedures performed, reaffirming the safety, practicality and reliability of this technology. However, there was no success in ultrasound-guided puncture in newborns, possibly associated with characteristics of the available equipment and devices, as well as the characteristics of newborns. Final considerations: PICC is a catheter that has been widely used in newborns for over 20 years, providing greater comfort and safety when it comes to venous therapy. Updates and improvements are necessary to refine the techniques for inserting the device in the neonatal population, already consolidated in other age groups, in order to increase the quality of care.

Downloads

Não há dados estatísticos.

Referências

BELEZA, L. D. O. et al.. Atualização das recomendações da prática quanto ao cateter central de inserção periférica em recém-nascidos. Revista Enfermagem UERJ, v. 29, 10 dez. 2021. DOI: ttps://doi.org/10.12957/reuerj.2021.61291

BOMFIM, J. M. S. et al.. Desafios na manutenção do cateter central de inserção periférica em neonatos. CuidArte, Enferm, p. 174–179, 2019.

DOYLE, S. C. et al.. Diagnostic accuracy of ultrasound for localising peripherally inserted central catheter tips in infants in the neonatal intensive care unit: a systematic review and meta-analysis. Pediatric Radiology, v. 52, n. 12, p. 2421–2430, 5 maio 2022. DOI: 10.1007/s00247-022-05379-7.

FRIDOLFSSON, P. E. J. Ultrasound-Guided Peripherally Inserted Central Catheter Placement in Extremely Low Birth Weight Neonates. Neonatal Network, v. 41, n. 1, p. 21–37, 1 jan. 2022. DOI: 10.1891/11-T-733

HAGEN, B. M. et al.. Tecnologias para manutenção do Cateter Central de Inserção Periférica em neonatos: revisão integrativa. Revista de Enfermagem da Universidade Federal de Santa Maria, v. 13, p. e4–e4, 8 fev. 2023. DOI: https://doi.org/10.5902/2179769270594

JOHNSON, K. N. et al.. Insertion of peripherally inserted central catheters in neonates less than 1.5 kg using ultrasound guidance. Pediatric Surgery International, v. 32, n. 11, p. 1053–1057, 2 set. 2016. DOI: 10.1007/s00383-016-3959-1.

KATHERIA, A. C.; FLEMING, S. E.; KIM, J. H. A randomized controlled trial of ultrasound-guided peripherally inserted central catheters compared with standard radiograph in neonates. Journal of Perinatology, v. 33, n. 10, p. 791–794, 13 jun. 2013. DOI: 10.1038/jp.2013.58

MITTANG, B. T. et al.. Cateter central de inserção periférica em recém-nascidos: fatores de retirada. Rev. baiana enferm, p. e38387–e38387, 2020. DOI: 10.1038/jp.2013.58

MUSSI, R. F. DE F.; FLORES, F. F.; ALMEIDA, C. B. DE. Pressupostos para a elaboração de relato de experiência como conhecimento científico. Práxis Educacional, v. 17, n. 48, p. 60–77, 1 set. 2021. DOI: https://doi.org/10.22481/praxisedu.v17i48.9010

OLETI, T. et al.. Does ultrasound guidance for peripherally inserted central catheter (PICC) insertion reduce the incidence of tip malposition? – a randomized trial. Journal of Perinatology, v. 39, n. 1, p. 95–101, 22 out. 2018. DOI: 10.1038/s41372-018-0249-x

OLIVEIRA, E. C. S. et al.. Usabilidade de bombas de infusão volumétricas em terapia intensiva pediátrica. Revista da Escola de Enfermagem da USP, v. 55, p. e03712, 10 maio 2021. DOI: https://doi.org/10.1590/S1980-220X2020001103712

OLIVEIRA, M. F.; VILAR, A. M. A.; SILVINO, Z. R. Aplicabilidade do ultrassom portátil para acessos venosos centrais em neonatos críticos: revisão de escopo. Research, Society and Development, v. 9, n. 8, p. e744986495, 31 jul. 2020. DOI: http://dx.doi.org/10.33448/rsd-v9i8.6495

SILVA, E. P. et al.. Técnica seldinger modificada: a importância de uma técnica diferenciada para inserção do cateter central de inserção periférica (PICC). Research, Society and Development, v. 11, n. 10, p. e301111032178, 1 ago. 2022. DOI: https://doi.org/10.33448/rsd-v11i10.32178

SOUZA, L. M. S.; SILVA, M. C. S. R.; CARDOSO, J. R. M. MANEJO DE CATETERES CENTRAIS EM RECÉM-NASCIDOS E CRIANÇAS INTERNADAS EM UNIDADES DE TERAPIA INTENSIVA. Revista Baiana de Enfermagem, v. 36, 2022. DOI: https://doi.org/10.18471/rbe.v36.44028

VILAR, A. M. A. et al.. Ultrassonografia Intervencionista para implantação e monitoramento de cateter venoso central de inserção periférica: scoping review. Revista Enfermagem UERJ, v. 28, p. e50366, 16 jul. 2020. DOI: https://doi.org/10.12957/reuerj.2020.50366

Downloads

Publicado

2024-05-30

Como Citar

Freitas, K., Ribeiro, L., Lima, L., Beleza, L., Santana, G., Nascimento, L., Ponce de Leon, C., & Schardosim, J. (2024). Use of ultrasound applied to the peripherally inserted central catheter in newborns: Utilização da ultrassonografia aplicada ao cateter central de inserção periférica em recém-nascidos. Concilium, 24(11), 281–294. https://doi.org/10.53660/CLM-3533-24L02

Edição

Seção

Articles